255.0.0.0. It is important to ensure that Art-Net data using the 2.x.x.x IP address scheme is not
routed onto the internet.
Ideally you should set up a separate network between your QuickQ console and node(s).
Unlike normal office networks, the IP address must be in the range 2.x.x.x or 10.x.x.x, where x
is between 0 and 255.
The subnet mask must be set to 255.0.0.0. This means configuring the address of each piece of
equipment on the network manually. QuickQ products are typically set to 10.x.x.x. from the
factory.
2021-03-12
QuickQ v6
65

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ChamSys QuickQ and is the answer not in the manual?

ChamSys QuickQ Specifications

General IconGeneral
Faders10
Universes1
DMX Outputs1
USB Ports1
Audio InputNo
DMX Channels512
Internal DisplayYes
Physical DMX outputs1
TypeLighting Controller
ConnectivityUSB
ProtocolsDMX512