INST.No.INE-868G [DB600] General Instruction Manual
- 8 -
1-2-4
Model code list
DB630
DB631(6)(7)(8)00(11)(12)(13)(14)
3: 48 x 48 size
1: PID control
2: Z control
1: ON-OFF pulse output type
3: Current output type
5: SSR drive pulse output type
6: Voltage output type
0: None
0: None
S: RS485 + 1 External input point [DI 1]
D: 5 External signal input points [DI1 to 5]
- : None
P: Available
0: None
1: 2 Alarm event output points [EV1, 2]
*1
0: None
: Refer to code table for adding option
*2
A: 100 to 240V AC
D: 24V AC/DC
*1 Alarm event only functions on mechanical relay, so check for the event function and select it.
*2 If one of following options is added, select an appropliate code for (13).
Code
Waterproof
specifications
Output scaling
Lower limit
burnout
Square root
calculation
1 - - -
A
*3
- - -
B - - -
C - - -
E
*3
- -
F - -
G - -
:Added option
*3 It can be specified when the control algorithm is PID control.
(4) Size
(5) Control algorithm
(6) Control output 1
(7) Control output 2 (Option)
(8) Communications interface + 1 External signal
input point/
5 External signal input points/ 5 Status event
output points (Open collector output) (Option)
(11) Programming function (Option)
(12) 2 Alarm event output points (Mechanical
relay output) (Option)
(13) Additional function
(14) Power voltage