INST.No.INE-868G [DB600] General Instruction Manual
- 160 -
9-2 Parameter list
Item Range Default Setting
O
p
eration screen
PV (measured value)
 to [°C"
:Over-range
:Under-range
SV (setting value)
 to [°C" □□□
Step time
 to [Hours:Minutes" □□
Output 1 value
 to [%"
Output 2 value
 to [%"
AUTO/
MANUAL switch
:AUTO output
:Manual output

Event status
:All events OFF
□□to
:All events ON
:Alarm event reset

Timer 1 elapsed time display
to [sec" □□□□
Timer 2 elapsed time display
to [sec" □□□□
CT measured value display
 to [A"
:Measured value not obtained
□□
FB measured value
display
 to [%" □□□
PID
auto tuning
□□
:Tuning not executed/forced to
terminate
:PID tuning for output 1 started
: PID tuning for output 2 started
:Tuning step 1
□□to
:Tuning step 4
□□ 
FB tuning
□□
:Tuning not executed/forced to
terminate
:FB tuning started

:FB tuning at zero side

:FB tuning at span side
Pattern repeat remaining
number display
to [times" □□□□
RUN/READY
switch
□□
:RUN status
:READY status
□□
Execution No. selection
for constant value
operation
 to □□
Pattern No. selection
 to □□
Program drive
:Program operation RESET
□□
:Program operation RUN

:Program operation STOP
□□
:Program operation ADVANCE
□□
:Program operation END

MODE0
Executing SV
 to [°C" □□□
Executing step time
 to [Hours:Minutes" □□
Executing event 1
 to 
Executing event 2
 to 
Executing event 3
 to 
Executing event 4
 to 
Executing P
:Two-position control
 to [%"
□□□
Executing I
to [sec" □□□
Executing D
to [sec" □□□
Executing output limiter L
 to [%" □□□
Executing output limiter H
 to [%" 
Executing guaranty soak
:Function OFF
 to [°C"
□□□
MODE1
SV rate of change for rise
:Function OFF
 to [°C"
□□□
SV rate of change for fall
:Function OFF
 to [°C"
□□□
SV rate of change unit

:Seconds

:Minutes
:Hours
□□
Constant value operation
PV start
:SV start (PV start OFF)
:PV start
□□□
Alarm action
at READY
:Alarm event not calculated in
READY status

:Alarm event calculated in
READYstatus
□□
MODE2
Program/
constant value
operation switch
:
Constant value operation (program operation OFF)

:Program operation (program operation ON)
□□□
Program operation
time unit
:[Hours:Minutes"
:[Minutes:Seconds"
□□□
Item Range Default Setting
SV in RESET
 to [°C" □□□
Pattern repeat
to [times" □□□
Operation screen
time display

:Step elapsed time
:Step remaining time

Pattern clear
:No pattern clear

:Initialize pattern No. 1
□□to

:Initialize pattern No. 4
:Initialize all patterns
□□ □□
Pattern copy

: No pattern copy
:Copy pattern No.1 to No.2
□□to
: Copy pattern No.4 to No.3
□□ □□
Number of steps
to:No step
to:1 to 12 steps
□□□□
Program operation PV
start
:SV start (PV start OFF)
:PV start
□□□
Start SV
 to [°C" □□□
SV for program
operation
 to [°C" □□□
Step time
 to [H:M, M:S" □□
Execution No.
selection for program
operation
:Keep the previous No
to
□□
(STEP1)
□□
(Other than
STEP1)
Output 1
at END
:
Constant value operation (AUTO output)
 to [%"

Output 2
at END
:
Constant value operation (AUTO output)
 to [%"

Linked
pattern No.
:No link
:Pattern No.1
to
:Pattern No.4
□□
MODE3
Grou
p
No.1
SV for constant value
operation
 to [°C" □□□
Event 1
 to 
Event 2
 to 
Event 3
 to 
Event 4
 to 
P
:Two-position control
 to [%"
□□□
I
to [sec" □□□
D
to [sec" □□□
Output limiter L
 to [%" □□□
Output limiter H
 to [%" 
Guaranty soak
:Function OFF
 to [°C"
□□□
Grou
p
No.2
SV for constant value
operation
 to [°C" □□□
Event 1
 to 
Event 2
 to 
Event 3
 to 
Event 4
 to 
P
:Two-position control
 to [%"
□□□
I
to [sec" □□□
D
to [sec" □□□
Output limiter L
 to [%" □□□
Output limiter H
 to [%" 
Guaranty soak
:Function OFF
 to [°C"
□□□
Grou
p
No.3
SV for constant value
operation
 to [°C" □□□
Event 1
 to 
Event 2
 to 
Event 3
 to 
Event 4
 to 
P
:Two-position control
 to [%"
□□□
I
to [sec" □□□
D
to [sec" □□□
Output limiter L
 to [%" □□□

Table of Contents