Remote Operation
Return Parameters : OFF | LIVE | TRIG
[SOURce :] CONFigure : EXTernal
Description : This command enables or disables the external controlled
analog signal input from external devices.
Query Syntax : [SOURce :] CONFigure : EXTernal?
Parameters : OFF | ON
Return Parameters : OFF | ON
[SOURce :] CONFigure : COUPling?
Description : This command sets the coupling mode to present AC source
output from external V reference : AC_AMPLIFIER and
DC_LEVEL_CTL.
Query Syntax : [SOURce :] CONFigure : COUPling?
Parameters : AC | DC
Return Parameters : AC | DC
7.6.2.5 PHASE Sub-system
[SOURce :]
PHASe
: ON
: OFF
[SOURce :] PHASe : ON
Description : This command sets the transition angle of the waveform when it
out. Default DEGREE ON is 0 degree.
Query Syntax : [SOURce :] PHASe : ON?
Parameters : <NR2>, valid range: 0.0 ~ 359.9
Return Parameters : <NR2>
[SOURce :] PHASe : OFF
Description : This command sets the transition angle of the waveform when it
quit.
Query Syntax : [SOURce :] PHASe : OFF?
Parameters : <NR2>, valid range: 0.0 ~ 360.0, 360.0: mean is IMMED.
Return Parameters : <NR2>
7.6.2.6 STATUS Sub-system
STATus
: OPERation
[: EVENt]?
: ENABle
: QUEStionable
: CONDition
: ENABle
: NTRansition
: PTRansition
STATus : OPERation [: EVENt]?
Description : This command queries the Operation Status register.