Programmable AC Source 61605 User’s Manual
Return Parameters : 1991.1
SYSTem : LOCal
Description : This command can only be used under the control of RS-232C.
If SYST : LOC is programmed, the AC source will be set in the
LOCAL state, and the front panel will work.
Query Syntax : NONE
Parameters : NONE
Return Parameters : NONE
SYSTem : REMote
Description : This command can only be used under the control of RS-232C.
If SYST : REM is programmed, the AC source will be set in the
REMOTE state, and the front panel will be disabled except the
“<PAGE/EXIT> key.
Query Syntax : NONE
Parameters : NONE
Return Parameters : NONE
7.7 Command Summary
Common Commands
* CLS Clear status
* ESE<n> Standard event status enable
* ESE? Return standard event status enable
* IDN? Return the AC source identification
* RCL<n> Recall the AC source file
* RST Reset the AC source to the initial states
* SAV<n> Save the AC source status
* SRE Set request enable register
* STB? Return status byte
* TST? Return the self-test result of the AC source
Instrument Commands
FETCh | MEASure
[ : SCALar]
: CURRent
: AC?
: DC?
: AMPLitude : MAXimum?
: CREStfactor?
: INRush
: FREQuency?
: POWer
: AC
[: REAL]?
: APParent?
: REACtive
: PFACtor?
:VOLTage