EasyManua.ls Logo

Chroma 61705 - Page 95

Chroma 61705
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
8-21
TRIG
TRIG : STATE?
[SOURce :] PULSe : VOLTage : AC
Description : This command sets AC voltage in the duty cycle of PULSE
mode.
Query Syntax : [SOURce :] PULSe : VOLTage : AC?
Parameters : <NR2>, valid range: 0.0 ~ 150.0 (in low range), 0.0 ~ 300.0 (in
high range)
Return Parameters : <NR2>
[SOURce :] PULSe : VOLTage : DC
Description : This command sets the DC voltage in the duty cycle of PULSE
mode.
Query Syntax : [SOURce :] PULSe : VOLTage : DC?
Parameters : <NR2>, valid range: -212.1 ~ 212.1 (in low range), -424.2 ~
424.2 (in high range)
Return Parameters : <NR2>
[SOURce :] PULSe : FREQuency
Description : This command sets the frequency during the duty cycle of
PULSE mode.
Query Syntax : [SOURce :] PULSe : FREQuency?
Parameters : <NR2>, valid range: 15.00 ~ 1000.00 (unit: Hz)
Return Parameters : <NR2>
[SOURce :] PULSe : SHAPe
Description : This command selects the waveform buffer for PULSE mode.
Query Syntax : [SOURce :] PULSe : SHAPe?
Parameters : A | B
Return Parameters : A | B
[SOURce :] PULSe : SPHase
Description : This command sets the start phase angle of duty cycle of
PULSE mode.
Query Syntax : [SOURce :] PULSe : SPHase?
Parameters : <NR2>, valid range: 0.0 ~ 359.9
Return Parameters : <NR2>
[SOURce :] PULSe : COUNt
Description : This command sets the number of times that the pulse is
executed before it is completed.
Query Syntax : [SOURce :] PULSe : COUNt?
Parameters : <NR2>, valid range: 0 ~ 65535
Return Parameters : <NR2>
[SOURce :] PULSe : DCYCle
Description : This command sets the duty cycle of PULSE mode.
Query Syntax : [SOURce :] PULSe : DCYCle?
Parameters : <NR2>, valid range: 0 % ~ 100 %
Return Parameters : <NR2>