Programmable AC Source 61705 User’s Manual
8-24
executed before it is completed.
Query Syntax : [SOURce :] STEP : COUNt?
Parameters : <NR2>, valid range: 0 ~ 65535
Return Parameters : <NR2>
OUTPut : MODE
Description : This command sets the operation mode
Query Syntax : OUTPut : MODE?
Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
Return Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
TRIG
Description : This command sets STEP mode in OFF, ON execution state
after setting OUTPut : MODE STEP. If users want to change
the parameters, it’s necessary to set TRIG OFF then OUTPut :
MODE FIXED. Then, set OUTPut : MODE STEP again to get
ready to set TRIG ON.
Query Syntax : TRIG : STATE?
Parameters : OFF | ON
Return Parameters : OFF | RUNNING
8.6.2.12 INTERHARMONICS Sub-system
[SOURce :]
INTerharmonics
: FREQuency
: STARt
: END
: LEVel
: DWELl
: MODe
OUTPut
: MODE
TRIG
TRIG : STATE?
FETCh | MEASure
: INTerharmonics
: FREQuency? Query the sweeping frequency
[SOURce :] INTerharmonics : FREQuency : STARt
Description : This command sets the start frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax : [SOURce :] INTerharmonics : FREQuency : STARt?
Parameters : <NR2>, valid range: 0.01 ~ 2400.00 (unit: Hz)
Return Parameters : <NR2>
[SOURce :] INTerharmonics : FREQuency : END
Description : This command sets the end frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax : [SOURce :] INTerharmonics : FREQuency : END?