EasyManua.ls Logo

Chroma 61705 - Page 98

Chroma 61705
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable AC Source 61705 Users Manual
8-24
executed before it is completed.
Query Syntax : [SOURce :] STEP : COUNt?
Parameters : <NR2>, valid range: 0 ~ 65535
Return Parameters : <NR2>
OUTPut : MODE
Description : This command sets the operation mode
Query Syntax : OUTPut : MODE?
Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
Return Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
TRIG
Description : This command sets STEP mode in OFF, ON execution state
after setting OUTPut : MODE STEP. If users want to change
the parameters, it’s necessary to set TRIG OFF then OUTPut :
MODE FIXED. Then, set OUTPut : MODE STEP again to get
ready to set TRIG ON.
Query Syntax : TRIG : STATE?
Parameters : OFF | ON
Return Parameters : OFF | RUNNING
8.6.2.12 INTERHARMONICS Sub-system
[SOURce :]
INTerharmonics
: FREQuency
: STARt
: END
: LEVel
: DWELl
: MODe
OUTPut
: MODE
TRIG
TRIG : STATE?
FETCh | MEASure
: INTerharmonics
: FREQuency? Query the sweeping frequency
[SOURce :] INTerharmonics : FREQuency : STARt
Description : This command sets the start frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax : [SOURce :] INTerharmonics : FREQuency : STARt?
Parameters : <NR2>, valid range: 0.01 ~ 2400.00 (unit: Hz)
Return Parameters : <NR2>
[SOURce :] INTerharmonics : FREQuency : END
Description : This command sets the end frequency of the sweep wave of
INTERHARMONICS mode.
Query Syntax : [SOURce :] INTerharmonics : FREQuency : END?

Table of Contents

Other manuals for Chroma 61705

Related product manuals