2-14 Installation
5160 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3207-001 Standard Revision A
Copyright
©
2013 Ciena
®
Corporation September 2013
A customer supplied cable can also be used provided it is shielded, the cable
is CAT 5 or better and the shield is terminated at both ends. This interface is
classified as intra-building only.
See “Installing a Sync Cable (Optional)” on page 2-26 for a procedure.
GPS/1PPS/TOD Cables
There are two ports on the 5160 that use the GPS/1PPS/TOD cable:
1PPS
•10MHz
Note: The 1PPS and 10MHz ports can be configured to be either input or
output references. These ports cannot provide both input and output
references simultaneously.
Ciena offers a cable (170-0085-900) for connection to these ports. The cable
is 6 feet long, with coax on one end and an SMB connector on the other.
This interface is classified as intra-building only.
To install an GPS cable, insert the mini-SMB connector into the port on the
device. Insert the tail end of the cable into the port on the terminating device.
Table 2-3
Sync Cable Wiring Connection Summary
Pair Color Signal Pin
1 White Rx tip 1
Blue Rx ring 2
2 White ToD/1PPS 3
Green ToD/1PPS 6
3 White Tx tip 4
Orange Tx ring 5
4White 7
Brown 8
Note: The wiring information in this table applies to both the available Ciena cables.