Installation 2-21
5160 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3207-001 Standard Revision A
Copyright
©
2013 Ciena
®
Corporation September 2013
8 Verify the power supply LEDs. The following LED indications should be
present on the 5160:
PSA - Status LED is solid green, Input LED is solid green
PSB - Status LED is solid green, Input LED is solid green
PWR - solid green
Note: The system does not distinguish between a faulty and an unpowered
supply. As a result, if redundant power supplies are installed, but only one
supply is connected to a power source, the unpowered supply will cause the
system to report an alarm state (ALRM LED solid yellow and STAT LED off).
This alarm will be cleared when the power supply is properly initialized.
The power supplies have now been installed and the system has been
powered on.