STOP
English
27 EN
The water doses for coffee and the hot water doses can
also be set using the "SELF-SETTING' function:
Hot water measures
1 - Press the button to be programed and keep it pressed
until the desired level is reached in the cup.
During this phase the time in seconds (top right of
GLVSOD\ LVLQFUHDVHG ZKHQWKH NH\ LVUHOHDVHG WKH
setting reached is memorized and appears below the
programmed key.
2 - Starting from step 1, continue programing, as desired,
on all the water buttons.
STOP
SELF-LEARNING
Group 1 DV: 000
090 150 080 160
26. Programming measures using the “SELF-LEARNING” function
SELF-LEARNING
water buttons t: 3.5
3.5 3.5
Coffee measures
)LOOWKH¿OWHUKROGHUZLWKWKHUHTXLUHGGRVDJHRIJURXQG
coffee and insert it in the dispenser unit.
3XWWKHFXSRUFRQWDLQHUXQGHUWKH¿OWHUKROGHUVSRXWV
and press the button to be programed. Keep it pressed
until the desired level is reached in the cup or container.
During this phase, the setting for the volumetric dosage
pulses (top right of display) is increased. When the key is
released, the setting reached is memorized and appears
under the programmed key.
3 - Starting from step 1, continue programing, as desired,
on all the coffee buttons.
press and hold the STOP button for at least 8 seconds
or until you hear a buzzer sound that will keep sounding
throughout the programing. The menu below will appear
on the display, showing the keys with the relative quantities
for water for the coffee.
:KHQ¿QLVKHGSUHVVWKH6723EXWWRQ7KHEX]]HUZLOOWXUQRIIWKXVFRQ¿UPLQJWKDWWKHSURJUDPLQJKDVEHHQFRPSOHWHG