97
Manual de Instrucciones
SVGm
ESPAÑOL
11.- CARACTERÍSTICAS TÉCNICAS
Tensión de red
Tensión asignada Un
SVGm-3WF-xxxx-480 SVGm-4WF-xxxx-400
208 ... 480 V~. F-F ± 10% 208 ... 400 V~ F-F ± 10%
SVGm-3WF-xxxx-690 SVGm-4WF-xxxx-550
230 ... 690 V~ F-F ± 10% 230 ... 550 V~ F-F ± 10%
Frecuencia Fn 50 / 60 Hz ± 5%
THD V máximo 25 %
Sistema de tierras TN, TT
Potencia
SVGm-3WF-030M
SVGm-4WF-020M
SVGm-3WF-060M
SVGm-4WF-040M
SVGm-3WF-075M
SVGm-4WF-050M
SVGm-3WF-100R
SVGm-3WF-100M
SVGm-4WF-069R
SVGm-4WF-069M
Consumo máximo 650 W 1300 W 1550 W 2070 W
Corriente máxima
SVGm-3WF-030M SVGm-3WF-060M SVGm-3WF-075M
SVGm-3WF-100R
SVGm-3WF-100M
44 A RMS 88 A RMS 108 A RMS 145 A RMS
SVGm-4WF-020M SVGm-4WF-040M SVGm-4WF-050M
SVGm-4WF-069R
SVGm-4WF-069M
30 A RMS 60 A RMS 72 A RMS 100 A RMS
Potencia
máxima
480V
SVGm-3WF-030M SVGm-3WF-060M SVGm-3WF-075M
SVGm-3WF-100R
SVGm-3WF-100M
30000 VA 60000 VA 75000 VA 100000 VA
400V
SVGm-4WF-020M SVGm-4WF-040M SVGm-4WF-050M
SVGm-4WF-069R
SVGm-4WF-069M
20700 VA 41400 VA 51750 VA 69000 VA
SVGm-3WF-100C-480
SVGm-4WF-069C-400
SVGm-3WF-200C-480
SVGm-4WF-138C-400
Tensión asignada de aislamiento Ui 480 V 480 V
Tensión soportada de impulso Uimp 4kV, CAT III Clase 1 4kV, CAT III Clase 1
Corriente asignada
SVGm-3WF-100C-480 SVGm-3WF-200C-480
145 A 290 A
SVGm-4WF-069C-400 SVGm-4WF-138C-400
100 A 200 A
Corriente de corta duración Icw 3.5 kA 1 segundo 3.5 kA 1 segundo
Corriente de cresta Ipk 84 kA pico 84 kA pico
Corriente de cortocircuito condicional Icc 40 kA 40 kA
Simultaneidad RDF 1 1
Consumo máximo 2070 W 4140 W
Corriente máxima
SVGm-3WF-100C-480 SVGm-3WF-200C-480
145 A RMS 290 A RMS
SVGm-4WF-069C-400 SVGm-4WF-138C-400
100 A RMS 200 A RMS
Potencia máxima
480V
SVGm-3WF-100C-480 SVGm-3WF-200C-480
100000 VA 200000 VA
400V
SVGm-4WF-069C-400 SVGm-4WF-138C-400
69000 VA 138000 VA