Error Message SW_VLAN-4-VTP_INVALID_DATABASE_DATA: VLAN manager received bad data of
type [chars] value [dec] from vtp database function [chars].
Explanation The VLAN manager received invalid data from a VTP configuration database routine.
The first [chars] is the data type, [dec] is the inappropriate value that was received, and the second
[chars] is the VTP database function.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message SW_VLAN-4-VTP_INVALID_EVENT_DATA: VLAN manager received bad data of
type [chars] value [dec] while being called to handle a [chars] event.
Explanation The VLAN manager received invalid data from the VTP configuration software. The
first [chars] is the data type, [dec] is the value of that data, and the second [chars] is the VTP event.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message SW_VLAN-4-VTP_SEM_BUSY: VTP semaphore is unavailable for function
[chars]. Semaphore locked by [chars].
Explanation The VTP database is not available. You should access the VTP database later. The first
[chars] is the function name that you want to configure, and the second [chars] is the function name
that is using the VTP database.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.

Table of Contents

Other manuals for Cisco 3110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 3110 and is the answer not in the manual?

Cisco 3110 Specifications

General IconGeneral
BrandCisco
Model3110
CategoryFirewall
LanguageEnglish

Related product manuals