This section contains the protocol tunneling message.
Error Message PT-3-PT_HW_UNAVAIL: Protocol Tunneling hardware resource not
available. [chars]
Note This message applies only to the Catalyst Switch Module 3110.
Explanation Protocol tunneling could not be enabled because no redirect registers are available.
Protocol tunneling requires redirect registers. [chars] is the hardware resource that is not available.
Recommended Action Disable any applications that use redirect registers, and try configuring the
protocol tunneling again.
QOSMGR Messages
This section contains the quality of service (QoS) manager messages. An incorrect QoS setting causes
these messages.
Error Message QOSMGR-3-FEATURE_NOT_FOUND: Cannot find feature for [chars].
Explanation An internal software error has occurred. [chars] is the description of the feature that the
software cannot find.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
running-config user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message QOSMGR-3-FILTERTYPE_INVALID: Internal Error Invalid Policy filtertype
[dec].
Explanation An internal software error has occurred. [dec] is the invalid filter type identification.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
running-config user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback