Chapter 2 Message and Recovery Procedures
PLATFORM_ENV Messages
PLATFORM_ENV Messages
This section contains platform-specific environment messages.
Error Message PLATFORM_ENV-1-FAN: Faulty fan detected.
Explanation A faulty fan is detected.
Recommended Action If the message appears again, immediately replace the switch fan.
Error Message PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present.
Explanation The fan is not in the switch.
Recommended Action If the fan is removable, remove and replace it into the switch. If the problem
persists after insertion, replace the fan.
Error Message PLATFORM_ENV-1-FRU_PS_ACCESS: [chars].
Explanation The switch failed to access the power supply due to a communication problem. [chars]
is the error message.
Recommended Action This problem could be transient. If the problem persists, replace the power
supply.
Error Message PLATFORM_ENV-1-TEMP: Abnormal temperature detected.
Explanation An abnormal temperature is detected.
Recommended Action Ensure that ambient temperature is not too high. If the problem persists, check
the switch temperature by entering the show env all privileged EXEC command.
PLATFORM_FBM Messages
This section contains the platform fallback bridging manager (FBM) messages.
Error Message PLATFORM_FBM-4-RECOVERED: Fallback bridging recovered from resource
crunch.
Explanation Fallback bridging has recovered from an earlier lack of resource.
Recommended Action No action is required.