2-111
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
VQPCLIENT Messages
Error Message VQPCLIENT-3-IFNAME: Invalid interface ([chars]) in response.
Explanation The VMPS has sent an unsolicited response with an unknown interface name. [chars] is
the name of the unknown interface.
Recommended Action Verify the VMPS configuration.
Error Message VQPCLIENT-3-THROTTLE: Throttling VLAN change on [chars].
Explanation An attempt was made to change the VLAN assignment for an interface more often than
once every 10 seconds. The VLAN change is denied. [chars] is the interface name.
Recommended Action No action is normally required. If the message recurs, verify the VMPS
configuration. Verify that unexpected hosts are not connected to the port.
Error Message VQPCLIENT-3-VLANNAME: Invalid VLAN ([chars]) in response.
Explanation The VMPS has specified a VLAN name that is unknown to the switch. [chars] is the
invalid VLAN name.
Recommended Action Make sure that the VLAN exists on the switch. Verify the VMPS configuration.
Error Message VQPCLIENT-7-NEXTSERV: Trying next VMPS [IP_address].
Explanation The system has lost connectivity with the current VMPS and is changing to the next
server in its list. [IP_address] is the address of the next server in the list.
Recommended Action This is a debug message only. No action is required.
Error Message VQPCLIENT-7-PROBE: Probing primary server [IP_address].
Explanation The system is trying to reestablish connectivity with the primary VMPS at the given IP
address.
Recommended Action This is a debug message only. No action is required.
Error Message VQPCLIENT-7-RECONF: Reconfirming VMPS responses.
Explanation The switch is reconfirming all responses with the VMPS.
Recommended Action This is only a debug message. No action is required.