2-14
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
CLS_ACC Messages
Error Message CLS_ACC-4-NO_HTTP_PAGE: Failed to locate HTTP page for the consoleless
access mode
Explanation The switch cannot find the HTTP page that appears in Express Setup mode because the
page is not on the flash memory.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message CLS_ACC-4-UNEXPECTEDEVENT: Switch does not support or not ready for
consoleless access mode
Explanation The switch does not support or is not ready to go into the consoleless access mode.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message CLS_ACC-5-CLRCFG: User cleared switch configurations under recovery
mode
Explanation In recovery mode, the switch resets to the default configuration.
Recommended Action No action is required.
Error Message CLS_ACC-5-RSTIMG: User reset switch image to factory default image
under recovery mode
Explanation In recovery mode, the switch image resets to the default image.
Recommended Action No action is required.
Error Message CLS_ACC-7-ACC_INTF: Selected management interface: [chars] interface
number: [dec]
Explanation An interface has been selected for Express Setup. [chars] is the name of the interface,
and [dec] is the number of the interface.
Recommended Action No action is required.