Chapter 2 Message and Recovery Procedures
GBIC_SECURITY Messages
Error Message GBIC_SECURITY-4-GBIC_INTERR: Internal error occurred in setup for GBIC
interface [chars].
Note This message applies only to the Catalyst Switch Module 3110X.
Explanation The system could not allocate resources or had some other problem during the setup for
the specified SFP module interface. [chars] is the interface in which the SFP module is installed.
Recommended Action Reload the switch by using the reload privileged EXEC command. If the
problem persists, find out more about the error by using the show tech-support privileged EXEC
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting IBM, see the
“Error Message Traceback
Reports” section on page 1-6.
Error Message GBIC_SECURITY-6-SFP_INSERTED: Transceiver SFP [chars] module inserted
in [chars]
Note This message applies only to the Catalyst Switch Module 3110X.
Explanation The online insertion and removal (OIR) facility detected a newly inserted transceiver
module for the interface specified in the message. The first [chars] is the module and the second
[chars] is the interface.
Recommended Action No action is required.
Error Message GBIC_SECURITY-6-SFP_REMOVED: Transceiver SFP [chars] module removed
from [chars]
Note This message applies only to the Catalyst Switch Module 3110X.
Explanation The online insertion and removal (OIR) facility detected the removal of a transceiver
module from the interface specified in the message. The first [chars] is the module and the second
[chars] is the interface.
Recommended Action No action is required.