A-28
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
OL-4266-08
Appendix A Online Diagnostic Tests
Exhaustive Memory Tests
TestFabricCh0Health
The TestFabricCh0Health test constantly monitors the health of the ingress and egress data paths for
fabric channel 0 on 10-gigabit modules. The test runs every five seconds. Ten consecutive failures are
treated as fatal and the module resets; three consecutive reset cycles may result in a fabric switchover.
TestFabricCh1Health
The TestFabricCh1Health test constantly monitors the health of the ingress and egress data paths for
fabric channel 1 on 10-gigabit modules. The test runs every five seconds. Ten consecutive failures are
treated as fatal and the module resets; three consecutive reset cycles may result in a fabric switchover.
Exhaustive Memory Tests
The exhaustive memory tests include the following tests:
TestFibTcamSSRAM, page A-29
TestAsicMemory, page A-29
TestAclQosTcam, page A-30
TestNetflowTcam, page A-30
Ta b l e A-49 TestFabricSCh0Health Test Attributes
Attribute Description
Disruptive/Nondisruptive Nondisruptive.
Recommendation Do not turn this test off. Use as a health-monitoring test.
Default On.
Release 12.1(13)E, 12.2(14)SX.
Corrective action
The module resets after 10 consecutive failures. Three
consecutive resets powers down the module.
Hardware support WS-X6704-10GE and WS-6702-10GE.
Ta b l e A-50 TestFabricCh1Health Test Attributes
Attribute Description
Disruptive/Nondisruptive Nondisruptive.
Recommendation Do not turn this test off. Use as a health-monitoring test.
Default On.
Release 12.1(13)E, 12.2(14)SX.
Corrective action
The module resets after 10 consecutive failures. Three
consecutive failures resets powers down the module.
Hardware support WS-X6704-10GE module.