Chapter 5 Web GUI Setup and Monitoring
232
12 From the Category drop-down list, choose the service to configure. If an input
service matches this type and Instance, then the Action will be applied. This
value is only used if the Action is set to Map. The categories are: UNKN, CDT,
LSDT, DATA, TTX, MPE, DPI, VBI, SUBT, AUD, VID, PCR or INVL.
13 Enter the Instance (1 to 64) of the service specified by Category to configure. If
an input service matches this type and instance, then the Action will be applied.
14 If the Action is set to Map, enter the output PID number (0 to 8192) in the
Output PID field.
15 Click Save.
16 Click OK.
To remove a PID mapping, click the radio button of the entry you want to
remove and click Delete.
Synchronizing the Inputs
1 In the DPM Program Entry Setup table, each PE output can be synchronized to
its input according to one of the four output modes. Click the radio button of the
program entry you want to synchronize and then click Resynchronize or click
Resynchronize All to synchronize the inputs to the outputs according to the
service assignments only. The Confirm Resynchronization window is displayed.
2 Click whether you want to synchronize the PE output according to the services
and then the PIDs assigned to each service, services only, PIDs only, or to
synchronize using a template.
Map Mode
Description
Resynchronize Program, PMT
PID, ES List & ES PIDs
The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
Resynchronize ES List
The receiver will synchronize the PE output according to
the available input services only, and ignore the input to
output service PID mapping.
Resynchronize ES PIDs
The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment
categories/names.
Resynchronize Template ES List
& PIDs
Allows you to preset the input to output mapping of a PE
according to the preset template. This is helpful in pre-
configuring any number of PEs for future use.
3 Click OK.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854-I and is the answer not in the manual?

Cisco D9854-I Specifications

General IconGeneral
BrandCisco
ModelD9854-I
CategoryReceiver
LanguageEnglish

Related product manuals