EasyManua.ls Logo

Cisco Prisma II - Receiver Alarm Data Parameters

Cisco Prisma II
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
Module Parameter Descriptions
112 78-4015908-01 Rev F
Receiver Alarm Data Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Nominal
Value
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Hysteresis
Operating
Range
Rx 1 Nominal
Input
InPwr1
1
-18.0 to
2.0 dBm in
0.5 step
-20 -4 3.2 3.2 1 OK or
Alarm
Rx 2 Nominal
Input
InPwr2
1
-18.0 to
2.0 dBm in
0.5 step
-20 -4 3.2 3.2 1 OK or
Alarm
Power
Supply Status
PsOk - - - - - - OK or
Alarm
Forced Alarm
Status
Alarm - - - - - - OK or
Alarm
Forced Alarm
Rx1 Status
2
Alarm1 - - - - - - OK or
Alarm
Forced Alarm
Rx2 Status
2
Alarm2 - - - - - - OK or
Alarm
AGC 1 Range
Status
AGC1Rng - - - - - - OK or
Alarm
AGC 2 Range
Status
AGC2Rng - - - - - - OK or
Alarm
CAN Bus
Status
2
CANBus - - - - - - OK or
Alarm
Redundant
Receiver 1
Alarm
2
RedRx1 - - - - - - OK or
Alarm
Redundant
Receiver 2
Alarm
2
RedRx2 - - - - - - OK or
Alarm
1
InPwr1 and InPwr2 values are reported to five decimal places, but for practical purposes,
only the first two digits should be regarded as significant.
2
Visible in LCI in Independent mode only.

Table of Contents