Receiver Alarm Data Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Nominal
Value
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Hysteresis
Operating
Range
Rx 1 Nominal
Input
InPwr1
1
-18.0 to
2.0 dBm in
0.5 step
-20 -4 3.2 3.2 1 OK or
Alarm
Rx 2 Nominal
Input
InPwr2
1
-18.0 to
2.0 dBm in
0.5 step
-20 -4 3.2 3.2 1 OK or
Alarm
Power
Supply Status
PsOk - - - - - - OK or
Alarm
Forced Alarm
Status
Alarm - - - - - - OK or
Alarm
Forced Alarm
Rx1 Status
2
Alarm1 - - - - - - OK or
Alarm
Forced Alarm
Rx2 Status
2
Alarm2 - - - - - - OK or
Alarm
AGC 1 Range
Status
AGC1Rng - - - - - - OK or
Alarm
AGC 2 Range
Status
AGC2Rng - - - - - - OK or
Alarm
CAN Bus
Status
2
CANBus - - - - - - OK or
Alarm
Redundant
Receiver 1
Alarm
2
RedRx1 - - - - - - OK or
Alarm
Redundant
Receiver 2
Alarm
2
RedRx2 - - - - - - OK or
Alarm
1
InPwr1 and InPwr2 values are reported to five decimal places, but for practical purposes,
only the first two digits should be regarded as significant.
2
Visible in LCI in Independent mode only.