Receiver Parameters
Receiver Operating Status Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Function
Operating
Range
Rx 1 Nominal
Input
InPwr1 Displays optical input power for Rx1 -20 dBm to
3.0 dBm
Rx 2 Nominal
Input
InPwr2 Displays optical input power for Rx2 -20 dBm to
3.0 dBm
Module
Temperature
ModTemp Displays module temperature -40 ºC to
100 ºC
AGC 1
Attenuator
AGC1Attn Attenuation used for AGC1 base settings 0 dB to
26.25 dB
AGC 2
Attenuator
AGC2Attn Attenuation used for AGC2 base settings 0 dB to
26.25 dB
AGC 1 Opt Inp
Pwr
AGC1OpIn Optical input power used for AGC1 base
settings
-18 dBm to
2.0 dBm
AGC 2 Opt Inp
Pwr
AGC2OpIn Optical input power used for AGC2 base
settings
-18 dBm to
2.0 dBm
Receiver 1
Status
Rx1 Indicates the status of Rx1:
Off = receiver disabled or in critical
alarm
Stby = receiver enabled with no alarms,
but in Slave mode (no RF output)
Active = receiver operating normally (RF
output active)
Off (0)
Stby (1)
Active (2)
Receiver 2
Status
Rx2 Indicates the status of Rx2:
Off = receiver disabled or in critical
alarm
Stby = receiver enabled with no alarms,
but in Slave mode (no RF output)
Active = receiver operating normally (RF
output active)
Off (0)
Stby (1)
Active (2)