Chapter 3 Operation using ICIM
60 78-4015908-01 Rev F
ALARMS Menus
When a module ALARMS menu is selected, press the
key or the
key to
scroll through alarms. Some typical ALARMS menus are shown below.
ALARMS
ALARMS
Shelf 5
Slot 12
TP154
Shelf 5
Slot 12
P 2 - HD- RXR-
HG
InPwr1
MajL
P 2 - HD- RXR-
HG
InPwr2
MajL
Note: For details on all alarm parameters, see Module Parameter Descriptions (on
page 107).
To Set Adjustable Alarm Thresholds using the ICIM
You can use the ICIM to change the adjustable alarm thresholds of this module from
their factory default values.
1 At the MODULE menu, press the
STAT
key.
Result: The STATUS menu appears on the ICIM LCD.
2 Press the
SEL
key. The alarm thresholds previously set are displayed. If the
label n/a is displayed, you cannot configure that alarm threshold. Press the
key to highlight the alarm threshold for the next parameter.
3 When the threshold that you wish to set is highlighted, press the
ENTER
key.
4 Press the
key or the
key to change the increment size.
5 Press the
key or the
key to adjust the alarm threshold.
Note: Press the Cancel (
ALRM
) key to return to the previous menu.
6 Press the
ENTER
key to save the changes.
Result: Data Saved displays.
7 When finished, press the
MAIN
key to return to the MAIN menu.