EasyManuals Logo
Home>Cisco>Network Router>SFE2000P

Cisco SFE2000P User Manual

Cisco SFE2000P
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
6-13
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-06
Chapter 6 Cabling the Line Ports and Completing the Installation
Information About Cascaded Systems
Connection mode — Redundancy is achieved by cascading two SCE platforms. Therefore the
connection mode for both SCE platforms may be either:
Inline-cascade
Receive-only-cascade
Physically-connected-links — For each of the cascaded SCE platforms, this parameter defines the
number of the link (Link 0 or Link 1) connected to this SCE platform.
Priority — For each of the cascaded SCE platforms, this parameter defines whether it is the primary
or secondary device.
On-failure — For each of the cascaded SCE platforms, this parameter determines whether the
system cuts the traffic or bypasses it when the SCE platform either has failed or is booting.
How to Configure the Connection Mode
Use the following command to configure the connection mode, including the following parameters:
inline/receive only
physically connected links
behavior upon failure of the SCE platform
primary/secondary
Step 1 From the SCE 2000(config if)# prompt, type connection-modeinline-cascade/receive-only-cascade[
physically-connected-links {link-0/link-1}] [ priority {primary/secondary}] [ on-failure
{bypass/cutoff}] and press Enter.
EXAMPLE 1
Use the following command to configure the primary SCE platform in a two-SCE platform inline
topology. Link 1 is connected to this SCE platform and the behavior of the SCE platform if a failure
occurs is bypass.
SCE 2000(config if)# connection-mode inline-cascade physically-connected-links link-1
priority primary on-failure bypass
EXAMPLE 2
Use the following command to configure the SCE platform that might be cascaded with the SCE
platform in Example 1. This SCE platform would have to be the secondary SCE platform, and Link 0
would be connected to this SCE platform, since Link 1 was connected to the primary. The connection
mode would be the same as the first, and the behavior of the SCE platform if a failure occurs is also
bypass.
SCE 2000(config if)# connection-mode inline-cascade physically-connected-links link-0
priority secondary on-failure bypass
How to Set the Link Mode
The SCE platform has an internal hardware card used to maintain the links even when the SCE platform
fails. This hardware card has four possible modes of operation:
bypass
forwarding

Table of Contents

Other manuals for Cisco SFE2000P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SFE2000P and is the answer not in the manual?

Cisco SFE2000P Specifications

General IconGeneral
BrandCisco
ModelSFE2000P
CategoryNetwork Router
LanguageEnglish

Related product manuals