7-11
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-06
Chapter 7 Basic SCE 2000 Platform Operations
Rebooting and Shutting Down the SCE Platform
2. Type reload shutdown.
3. Type y to confirm the shutdown request and press Enter.
DETAILED STEPS
Step 1 Connect to the serial console port (The CON connector on the SCE platform front panel, 9600 baud).
The SCE 2000# prompt appears.
Step 2 Type reload shutdown.
A confirmation message appears.
Step 3 Type y to confirm the shutdown request and press Enter.
Examples for Shutting Down the SCE Platform
The following example shows the commands for system shutdown.
SCE 2000#reload shutdownYou are about to shut down the system.
The only way to resume system operation after this
is to cycle the power off, and then back on.
Continue?
y
IT IS NOW SAFE TO TURN THE POWER OFF.
Note Since the SCE platform can recover from the power-down state only by being physically turned off (or
cycling the power), this command can only be executed from the serial CLI console. This limitation
helps prevent situations in which a user issues this command from a Telnet session, and then realizes
he/she has no physical access to the SCE platform.