Administration: Stack Management
Unit Failure in Stack
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x 124
7
The following shows an example of auto numbering when a master-enabled unit joins the
stack. There are two units with unit ID = 1. The master selection process selects the best unit to
be the master unit. The best unit is the unit with the higher uptime in segments of 10 minutes.
The other unit is made the backup.
Auto-numbered Master-enabled Unit
The following shows what happens when a user-assigned, master-enabled unit with Unit ID 1
joins a stack that already has a master unit with user-assigned unit ID 1. The newer Unit 1 does
not join the stack and is shutdown.
User-assigned Master-enabled Unit
Unit Failure in Stack
This section includes the following topics:
Failure of Master Unit
Master/Backup Switchover

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350X-24 and is the answer not in the manual?

Cisco SG350X-24 Specifications

General IconGeneral
ModelSG350X-24
LayerLayer 3
Power SupplyInternal
Rack MountableYes
RAM512 MB
Flash Memory256 MB
MAC Address Table16K entries
Power over Ethernet (PoE)No
Uplink Ports4 x 10 Gigabit Ethernet
Jumbo Frame SupportYes
Power Dedicated to PoENot applicable
Dimensions440 x 44 x 350 mm
StackingYes
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Relative Humidity10% to 90% (non-condensing)
Power Consumption30W (maximum)