Multicast
IPv4 Multicast Configuration
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x 248
14
STEP 9 Click Apply. The Running Configuration file is updated.
IPv4 Multicast Configuration
The following pages configure IPv4 Multicast Configuration:
IGMP Snooping
IGMP Interface Settings
IGMP VLAN Settings
•IGMP Proxy
IGMP Snooping
To support selective IPv4 Multicast forwarding, bridge Multicast filtering must be enabled (in
the Properties page), and IGMP Snooping must be enabled globally and for each relevant
VLAN in the IGMP Snooping page.
To enable IGMP Snooping and identify the device as an IGMP Snooping Querier on a VLAN:
STEP 1 Click Multicast > IPv4 Multicast Configuration > IGMP Snooping.
When IGMP Snooping is globally enabled, the device monitoring network traffic can
determine which hosts have requested to receive Multicast traffic. The device performs IGMP
Snooping only if both IGMP snooping and Bridge Multicast filtering are enabled.
The IGMP Snooping Table is displayed. The fields displayed are described in the Edit page
below. In addition the following fields are displayed:
IGMP Snooping Status—Displays whether IGMP Snooping was enabled
(Administrative) and whether it is actually running on the VLAN (Operational).
IGMP Querier Status—Displays whether IGMP Querier was enabled
(Administrative) and whether it is actually running on the VLAN (Operational).
Enable or disable the following features:
IGMP Snooping Status—Select to enable IGMP snooping globally on all interfaces.
IGMP Querier Status—Select to enable IGMP querier globally on all interfaces.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350X-24 and is the answer not in the manual?

Cisco SG350X-24 Specifications

General IconGeneral
ModelSG350X-24
LayerLayer 3
Power SupplyInternal
Rack MountableYes
RAM512 MB
Flash Memory256 MB
MAC Address Table16K entries
Power over Ethernet (PoE)No
Uplink Ports4 x 10 Gigabit Ethernet
Jumbo Frame SupportYes
Power Dedicated to PoENot applicable
Dimensions440 x 44 x 350 mm
StackingYes
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Relative Humidity10% to 90% (non-condensing)
Power Consumption30W (maximum)