Dashboard
Stack Topology
29 Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
2
In table view, there is no need to select a specific stack unit. Information is displayed in
table form, as shown below:
The following fields are displayed:
- Interface—Port or LAG that was suspended
- Suspension Reason—Reason interface was suspended
- Auto-recovery current status—Has auto recovery been enable for the feature that
caused the suspension.
The following configuration options (right-hand corner) are available:
Display Mode—Select either Device View or Table View.
Refresh Time—Select one of the options displayed.
Error Recovery Settings—Click to open Error Recovery Settings.
Stack Topology
NOTE Stacking is only supported on the SG350 (except for the Sx350) and SG550 family of devices.
This module is a graphic representation of the stack topology and is identical in behavior to the
Stack Topology View section in the Stack Management screen, as shown below:
The following fields are displayed:
Stack Topology—Either Chain or Ring (see Types of Stack Topology).
Stack Master—Number of unit functioning as the master unit of the stack.
Hovering over a unit in the module displays a tooltip identifying the unit and providing basic
information on its stacking ports.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350X-24 and is the answer not in the manual?

Cisco SG350X-24 Specifications

General IconGeneral
ModelSG350X-24
LayerLayer 3
Power SupplyInternal
Rack MountableYes
RAM512 MB
Flash Memory256 MB
MAC Address Table16K entries
Power over Ethernet (PoE)No
Uplink Ports4 x 10 Gigabit Ethernet
Jumbo Frame SupportYes
Power Dedicated to PoENot applicable
Dimensions440 x 44 x 350 mm
StackingYes
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Relative Humidity10% to 90% (non-condensing)
Power Consumption30W (maximum)