EasyManuals Logo

Cisco SG350X-24 User Manual

Cisco SG350X-24
725 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #276 background imageLoading...
Page #276 background image
VLAN Management
Regular VLANs
215 Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
11
- Multicast TV VLAN—When the port is in Access mode, it will be a member of this
Multicast TV VLAN.
Trunk Mode Membership
- Native VLAN ID—When the port is in Trunk mode, it will be a member of this
VLAN.
- Tagged VLANs—When the port is in Trunk mode, it will be a member of these
VLANs. The following options are possible:
All VLANs—When the port is in Trunk mode, it will be a member of all VLANs.
User Defined—When the port is in Trunk mode, it will be a member of the VLANs
that are entered here.
General Mode Membership
- Untagged VLANs—When the port is in General mode, it will be an untagged
member of this VLAN.
- Tagged VLANs—When the port is in General mode, it will be a tagged member of
these VLAN
- Forbidden VLANs—When the port is in General mode, the interface is not allowed
to join the VLAN even from GVRP registration. When a port is not a member of
any other VLAN, enabling this option on the port makes the port part of internal
VLAN 4095 (a reserved VID)
- General PVID—When the port is in General mode, it will be a member of these
VLANs.
Customer Mode Membership
- Customer VLAN ID—When the port is in Customer mode, it will be a member of
this VLANs.
- Customer Multicast VLANs—When the port is in Customer mode, it will be a
member of this Multicast TV VLANs.
STEP 5 Select a port and click Details to view the following fields:
Administrative VLANs—Port is configured for these VLANs.
Operational VLANs—Port is currently a member of these VLANs.
STEP 6 Click Apply (for Join VLAN). The settings are modified and written to the Running
Configuration file.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350X-24 and is the answer not in the manual?

Cisco SG350X-24 Specifications

General IconGeneral
ModelSG350X-24
LayerLayer 3
Power SupplyInternal
Rack MountableYes
RAM512 MB
Flash Memory256 MB
MAC Address Table16K entries
Power over Ethernet (PoE)No
Uplink Ports4 x 10 Gigabit Ethernet
Jumbo Frame SupportYes
Power Dedicated to PoENot applicable
Dimensions440 x 44 x 350 mm
StackingYes
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Relative Humidity10% to 90% (non-condensing)
Power Consumption30W (maximum)