Administration: Discovery
Configuring CDP
147 Cisco 500 Series Stackable Managed Switch Administration Guide Release 1.3
9
Syslog Voice VLAN Mismatch—Select to enable the option of sending a
SYSLOG message when a voice VLAN mismatch is detected This means
that the voice VLAN information in the incoming frame does not match what
the local device is advertising.
Syslog Native VLAN Mismatch—Select to enable the option of sending a
SYSLOG message when a native VLAN mismatch is detected. This means
that the native VLAN information in the incoming frame does not match what
the local device is advertising.
Syslog Duplex Mismatch—Select to enable the option of sending a
SYSLOG message when duplex information mismatch is detected. This
means that the duplex information in the incoming frame does not match
what the local device is advertising.
STEP 3 Enter the relevant information, and click Apply. The port settings are written to the
Running Configuration.
Displaying CDP Local Information
To view information that is advertised by the CDP protocol about the local device:
STEP 1 Click Administration > Discovery - CDP > CDP Local Information.
STEP 2 Select a local port, and the following fields are displayed:
Interface—Number of the local port.
CDP State—Displays whether CDP is enabled or not.
Device ID TLV
- Device ID TypeType of the device ID advertised in the device ID TLV.
- Device ID—Device ID advertised in the device ID TLV.
System Name TLV
- System NameSystem name of the device.
Address TLV
- Address1-3—IP addresses (advertised in the device address TLV).
Port TLV

Table of Contents

Other manuals for Cisco SG500-28

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG500-28 and is the answer not in the manual?

Cisco SG500-28 Specifications

General IconGeneral
Ports28
Port TypeGigabit Ethernet
LayerLayer 3
Switching Capacity56 Gbps
PoE SupportNo
Form FactorRack-mountable
RAM256 MB
Flash Memory32 MB
Power SupplyInternal
Jumbo Frame Support9KB
VLAN SupportYes
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% non-condensing
Dimensions17.3 x 10.2 x 1.7 in (440 x 260 x 44 mm)
MAC Address Table Size16, 000 entries

Related product manuals