57
100 – Mobile Lite Emergency (emergency)
When the Active Button of Mobile Lite is pressed (“Help Event” set as
100).
101 – Personal Emergency (emergency)
When the Active Button of Mobile Lite is pressed (“Help Event” set as
101).
When the Active Button of the learnt-in Fall Sensor, WTR or Panic
Button is pressed.
102 – Inactivity (emergency)
When a Fall Sensor remains stationary for 10 seconds after fall
detection.
120 – Fall Detection / Panic (emergency)
When a fall is detected from the learnt-in Fall Sensor.
When the Active Button of Mobile Lite is pressed (“Help Event” set as
120).
158 – High Temperature Detected (emergency)
When the ambient temperature detected rises above high
temperature level.
159 – Low Temperature Detected (emergency)
When the ambient temperature detected drops below low
temperature level.
301 – AC Fail/Restore (status)
When AC is disconnected (fail)
When AC is re-connected(restored)
302 – Mobile Lite Low on Battery (status)
When Mobile Lite is low on battery.
311 – Amplifier Base ’s Battery Disconnected (status)
When the Amplifier Base’s battery is not connected.
384 – RF Device Low on Battery (status)
When the learnt-in RF Fall Sensor, WTR or Panic Button is low on
battery.
602 – Auto Check-In Report (status)
When Mobile Lite makes an auto check-in report to the CMS.
643 – Location Accuracy Deviation (status)
When the margin of error for locating Mobile Lite is too great.
644 – GPS/Cell Locate Time Out (status)
When Mobile Lite is unable to acquire any GPS/Cell Locate position
within reporting time limit.