EasyManua.ls Logo

ClipperCreek HCS - Chargeguard EX

ClipperCreek HCS
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HCS User Manual
32
ChargeGuard
TM
EX Enabled HCS
ChargeGuard
TM
EX provides a simple interface to connect the
ClipperCreek HCS EVSE to an existing building access control or
other third party access control system. With ChargeGuard
TM
EX
a momentary contact closure driven by successful authentication
in an access control system can activate the HCS ChargeGuard
TM
EX enabled station for a single charging session. Alternatively,
maintaining the contact closure will leave the station enabled for
multiple charging sessions until the connection is released.
When the Orange and Yellow control wires are shorted together,
the EVSE is “ON” and ready to charge a vehicle. When the
wires are disconnected, the station is “OFF” and requires a valid
activation through the access control system in order to begin
charging again.
ChargeGuard
TM
EX can be utilized in two ways:
1. If individual access control is desired (for each charge
session), the access control system will need to provide
a momentary short to the orange and yellow wires
which will activate the station for a single charge
session. In this implementation once the vehicle is
disconnected the station will require a successful
authorization through the access control system.
2. If open access is desired, connect the orange and yellow
wires for as long as open access is desired. As long
as the orange and yellow wires are shorted together, the
station will be enabled for use.