Ruckus ICX 7450 Switch Hardware Installation Guide 77
Part Number: 53-1003899-09
Weight and physical dimensions
Environmental requirements
Model Height Width Depth Weight (with
basic modules)
Fully loaded weight
(no transceivers)
ICX 7450-24 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
6.40 kg
14.11 lb
8.57 kg
18.89 lb
ICX 7450-24P 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
6.90 kg
15.21 lb
9.02 kg
19.89 lb
ICX 7450-32ZP 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
7.14 kg
15.74 lb
8.91 kg
19.64 lb
ICX 7450-48 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
6.50 kg
14.33 lb
8.74 kg
19.20 lb
ICX 7450-48P 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
7.10 kg
15.65 lb
9.21 kg
20.30 lb
ICX 7450-48F 4.37 cm
1.72 inches
40.00 cm
17.32 inches
39.37 cm
15.50 inches
6.80 kg
14.99 lb
8.94 kg
19.71 lb
Condition Operational Non-operational
Ambient Temperature -5°C to 50°C (23°F to 122°F)
NOTE: Maximum operation temperature of 50°C applies to sea level
and decreases by 1°C for every 1000 feet altitude increase
per NEBS rule. If Back-to-Front airflow is chosen and only a
single fan is in service, maximum operation temperature
decreases by 5°C.
-40°C to 70°C (-40°F to 158°F)
Relative Humidity (non-condensing) 10% to 90% at 50°C (122°F) 5% to 95% at 70°C (158°F)
Altitude (above sea level) 0 to 3,048 m (10,000 ft) 0 to 12,000 m (39,370 ft)
Shock 20 G, 11 ms, half-sine wave 33 G, 11 ms, half-sine wave
Vibration 1 G sine, 0.4 grms random, 5-500 Hz 2.4 G sine, 1.1 grms random, 5-500 Hz
Airflow Nominal: 5-7 cfm, Maximum: 17-20 cfm. N/A
Heat dissipation
(+/- 5%)
NOTE: Refer to “Power consumption (typical configuration)” on
page 78 and “Power consumption (maximum configuration)”
on page 79 for detailed information on heat dissipation.
N/A