NBLB2 Service Manual
32
CMD
DATA
Description
return
0x01 : Set smart charge. Others :
None
60h
Enable FnKey of sticky key function(Support by
ToshibaPowerSaver)
None
61h
Disable FnKey of sticky key function(Support
byToshibaPowerSaver)
None
62h
Fn key down (Support by ToshibaPowerSaver)
None
63h
Fn Key Up(Support by ToshibaPowerSaver)
None
64h
Enable scancode for test button
None
65h
Disable scancode for test button
None
66h
Disable WDT wake funtion in deep sleep
None
67h
Enable WDT wake funtion in deep sleep(Default)
None
70h
Sticky key mode enable (for no AP support used)
None
71h
Sticky key mode disable (for no AP support used)
None
76h
Disable FAN speed full on
None
77h
Enable Fan speed full on
None
78h
Disable FAN fine tune function
None
79h
Enable FAN fine tune function
None
80h
Charge Limit function (Not enable)
0
Data xx : Charge battery to 100% and discharge to xx%
None
81h
Charge Limit function
0
Data xx : Charge or Discharge to xx%
None
82h
Disable Charge Limit function
None
90h
One touch button application allow to send scan
code(user button) if user pressed
None
91h
One touch button application don‟t allow to send scan
code(user button) if user pressed
None
94h
Mute on
None
95h
Mute off
None
9Ah
Disable AC power source
None
9Bh
Enable AC power source
None
9Ch
Enable LID switch resume function
None
9Dh
Disable LID switch resume function
None