NBLB2 Service Manual
55
Offset
Description
E0h
Battery over voltage counter
E1h
Communication fail counter
E2h
Battery voltage of ADC
E3h-E4h
Cell1 voltage
E5h-E6h
Cell2 voltage
E7h-E8h
Cell3 voltage
E9h-EAh
Cell4 voltage
F0h
Battery staus1
Bit0 Battery exist
Bit1 Battery full
Bit2 Battery empty
Bit3 Battery first in
Bit4-5 reserved
Bit6 Battery read complete
Bit7 Use LI_ION or NI_MH#
F1h
Battery staus2
Bit0 Low low battery
Bit1 Check EDV1
Bit2 Set EDV1
Bit3 Battery shutdown 5%
Bit4 Start to read battery
Bit5 Start to count communication counter
F2h
Battery stop charge status(low byte)
Bit0 Battery fast charging timeout
Bit1 Battery bad cell
Bit2 Battery communication fail
Bit3 Use for detect battery charging suspend
Bit4 Battery command stop charge
Bit5 Battery stop charge for Customer use
Bit6 Battery over voltage
Bit7 Battery over temperature
F3h
Battery stop charge status(high byte)
Bit0 Battery trickle charging timeout
Bit1 Stop charge of Adapter throttling
Bit2 Stop charge of Sony battery