53
1.4.2.6 Environmental limits
Conel Flow Rain-
Champion Location:
• Dry and frost-free room (e.g. basement);
• room with oor drain to the sewer;
• Ensure emergency over ow - discharge into sewer or lifting system using
a DN70 pipe;
• Mount the Conel Flow Rain-Champion horizontally on a at wall, with
suf cient distance (we recommend at least 30cm - preferably as large a
distance as possible) below the ceiling;
• Install and assemble Conel Flow Rain-Champion with low vibration.
Storage • In the dry state - feed tank, pump and lines of the Conel Flow Rain-Cham-
pion completely emptied => storage temperature: -15 ° C to + 50 ° C.
Handling: • The Conel Flow Rain-Champion must not be exposed to any avoidable
impacts or collisions;
Temperature ranges
of the media to be
pumped:
• Temperature of the pumped medium:> (frost-free) to + 40 ° C.
Operation: • The Conel Flow Rain-Champion is suitable for continuous operation.
• A longer operation of the Conel Flow Rain-Champion with a throughput
that is below the minimum value speci ed on the data sheet can excessive
heating that is harmful to the pump.
• At water temperatures close to 40°C, the minimum throughput must be
increased depending on the temperature. For liquids other than water,
please contact customer service.
ATTENTION:
• The Conel Flow Rain-Champion must never be operated „dry“ (i.e. in a dry
state) - property damage is most likely the result.
1.4.2.7 Media quality of the rainwater
hydrological data maximum Units
PH value 6.0 -8.0
conductivity < 150 mS/m
total hardness < 15 °dH
carbonate hardness < 4 °dH
Chloride CL < 100 mg/l
Sulfate So4 < 150 mg/l
Ammonium < 1 mg/l
Iron Fe < 0.2 mg/l
Manganese < 0.1 mg/l
solid amount (sand) < 150 g/m
3
solid size < 2.0 Mm