EasyManua.ls Logo

Conel FLOW - Initial Commissioning; Commissioning Security Precautions

Conel FLOW
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74
Faulty electrical connections;
- check the connection of the power supply - is voltage (230V/50Hz);
- as soon as the required mains voltage is attached, the „POWER“ LED lights up.
The pump housing is not  lled with water.
- the safety system has been triggered and the LED „POWER“ lights up, the LED“ERROR“ lights
up.
- Fill pump housing with water and then restart (RESET button press).
The pump is blocked.
- the LED „POWER“ as well as the LED „ERROR“ light up, the safety system has been triggered. By
pressing the „RESET - Button“ lights the „ON“ LED, but the pump does not start. In this case,
contact technical support.
Air inlet at the pump;
- pressure is signi cantly lower than the nominal pressure or there are constant  uctuations. The
safety system stops the operation of the pump and triggers an error message;
- The LED „POWER“ and the LED „ERROR“ light up.
- Check the sealing of the connectors and the seals of the intake shaft.
Pump is constantly running:
- possible leakage in the piping system;
- check all sampling points for leaks – especially hoses and mobile sampling points (e.B. garden
syringe, etc.).
9 INITIAL COMMISSIONING OF THE
CONEL FLOW RAIN-CHAMPION
9.1 SECURITY
Risk:
All commissioning activities may only be carried out by professional and
knowledgeable personnel who have been suf ciently informed by studying the
operating instructions in-depth;
Do NOT wear your personal protective gear and do NOT work with wet hands
or wet feet or stand in the water – avoid a fatal electric shock.
Before starting work of any kind, please ensure that the power supply has been
interrupted (e.g. pull the power plug) and secure it again against unauthorized or
unintentional re-engagement;
As soon as the Conel Flow Rain-Champion is put into operation, no persons
oranimalsmaybeintheconveyingmedium(storage)–dangertolifedueto
electric shock;
Ensure that the Conel Flow Rain-Champion cannot be put into operation wit-
hout authorisation or unintentionally during commissioning;
Make sure that the electrical connectors are in the  ood-proof area or are
protected from moisture.
Refer to unauthorized persons (especially children, adolescents) or animals from
the  eld of work and activity.
Attention:
The temperature of the conveying  uid shall not exceed the maximum tempera-
ture speci ed in the technical data;
The Conel Flow Rain-Champion must not be operated in impure water under
any circumstances.

Table of Contents