Empty the feed-in tank and the pump housing as much as possible – with a  lled tank, the Conel Flow
Rain-Champion has a very high weight.
Loosen the two fastening screws at the top of the feed tank (see Figure 8.2.3);
Lift Conel Flow Rain-Champion of the wall rail bracket - use suitable vertical devices.
Dismantling the wall support bracket from the wall.
Danger from shock and crush injuries
Always wear your personal protective equipment and be careful when dis-
mantling;
Empty the feed tank and the pump housing as much as possible – with a  lled
tank, the Conel Flow Rain-Champion has a very high weight - use lowering/
lifting devices for lifting.
11 TROUBLESHOOTING
11.1 SECURITY
Improper performance of activities during troubleshooting can cause death,
grievous bodily harm and damage to the pump.
Have all the above-mentioned work carried out only by professional and
knowledgeable personnel.
This staff must have read and understood these operating instructions.
Turn the pump off without voltage and secure it against unauthorized or un-
intentional switching on.
Ensure that the Conel Flow Rain-Champion cannot be used without authori-
zation or unintentionally during troubleshooting;
11.2 ERROR STATE DETECTION
If the Conel Flow Rain-Champion is working incorrectly, this may be noticeable at the following points:
The pump switching machine displays a fault according to the status display;
Unusual noises can be heard on the Conel Flow Rain-Champion;
The electrical safety parts are triggered.
11.3 FIRST MEASURES TO ELIMINATE FAULTS
Check the following circumstances:
Press the „RESET button“ and acknowledge the fault;
Check the raw line system for leaks;
Check water level in the storage?
If necessary, check  lters in the memory on the suction line and, if necessary, clean them:
Are all picking points closed?
Check the electrical r fault current circuit breaker and the associated circuit breaker in the control
cabinet - if necessary switch it back on?
If you are not able to detect any disturbance, please refer to the following chapter“.
11.4 FURTHER MEASURES TO ELIMINATE FAULTS
Note:
If you cannot locate or repair the fault yourself or if you are unable to  x it,
please contact your electrical/sanitary department or directly to the manufac-
turer (contact details see chapter 1.5).