Menu 17
Parameter
structure
Keypad and
display
Parameter x.00
Parameter
description format
Advanced parameter
descriptions
Serial comms
protocol
Electronic
nameplate
Performance
186 Digitax ST Advanced User Guide
www.controltechniques.com Issue Number: 1
When this parameter is 0, the Motion Processor will be reset when a drive trip is cleared. When set to 1, the Motion Processor will be unaffected by a
drive trip reset (i.e. continue running)
Defines the action taken if a user DPL program attempts to write an out of range value to a parameter. When set at 1, a run-time trip will occur
(number 44); when set at zero the value will automatically be limited to the maximum/minimum of that parameter.
17.15 Disable reset on trip cleared
Digitax ST Variant Indexer, Plus
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Range OFF (0) or On (1)
Default OFF (0)
Update rate 4ms write
17.16 Encoder data update rate
Digitax ST Variant Indexer, Plus
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Range 0 to 3
Default 0
Update rate 4ms write
Display Description
0
APC data and menu 90 encoder parameters are updated
every 250µs.
1
APC data and menu 90 encoder parameters are updated
immediately prior to every POS task.
2
APC data and menu 90 encoder parameters are updated
immediately prior to every CLOCK task.
3
APC data and menu 90 encoder parameters are never
updated. If these are never updated, more processor resource
will become free.
17.17 Enable parameter over range trips
Digitax ST Variant Indexer, Plus
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Range OFF (0) or On (1)
Default OFF (0)
Update rate 4ms write