Connecting up the combi steamer
Installation manual 65
Installing the gas supply
Follow the steps below to provide the gas supply for your combi steamer:
Step Action
1
Measure the supply flow pressure.
2 Compare the type of gas, the gas pressure and the rating for the gas supply connection with the data
given on the appliance type plate.
3
Fit a pressure reducer if the supply flow pressure is too high.
4
Connect the gas supply.
5 Check that all connections inside and outside the appliance are sealed (e.g. using gas detector or
leak locator spray).
Caution
Do not spray leak locator spray on the flame-monitor electrical leads.
6
Inform the user that the gas components must be serviced annually.
7 Check the flue-gas values against the figures given in the "Gas valve installation instructions" held in
the wiring compartment.
Carry out a flue gas analysis.
Check that the analysis values lie within the permitted flue gas values given in the table above.
Record the measurements in the appliance.
8
Once the gas installation is finished, close the gas shut-off device.
Flue gas value records
You can use the table below to keep records of flue gas values:
O
2
λ
CO
2
CO Gas type
[%]
[%] [ppm]