Connecting up the combi steamer
Installation manual 45
► Electrical installation
Meaning
It is crucial to safe and reliable operation of the combi steamer that the electrical system is installed
carefully and correctly. All the rules and regulations listed here, and the described procedure, must be
strictly followed.
Eligibility of installation personnel
Only electricians qualified under the terms of EN 50110-1 and from an approved customer service
office are permitted to connect the combi steamer.
Equipment provided by customer and electrical installation regulations
The table below shows what equipment must be provided by the customer and what regulations must
be observed when connecting the appliance.
Equipment Regulations
Fuse Fuse-protection and connection of the combi steamer must comply with local
regulations and national installation requirements.
Equipotential bonding The combi steamer must be incorporated in an equipotential bonding system.
Equipotential bonding: electrical connection that ensures that the frames of electri-
cal equipment and any external conductive components are at an equal (or practi-
cally equal) potential.
Ground fault circuit
interrupter
A suitable ground fault circuit interrupter in compliance with national regulations
must be incorporated in the installation of the combi steamer.
The ground fault circuit interrupter must not be used to protect any other appli-
ances.
Disconnection device An easily accessible all-pole disconnection device with a minimum contact separa-
tion of 3 mm must be installed close to the appliance. The combi steamer must be
connected via this disconnection device.
The disconnection device is used to disconnect the appliance from the electrical
supply for cleaning, repair and installation work.
Implementation regulations
The electrical supply connection must be implemented in compliance with the following regulations:
VDE (0100/0700) or relevant regulations of local professional associations
Currently valid regulations of the local power supply company
Power cord
The power cord must be an oil-resistant, sheathed and flexible cable in accordance with IEC 60245
(e.g. H05RN-F, H07RN-F). A maximum cable length of 5 m is recommended.
Phase and direction of rotation
The appliance does not need to be connected in a specific phase configuration or direction of rotation.