EasyManua.ls Logo

Copley Controls Xenus Plus Series - Page 108

Copley Controls Xenus Plus Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 108
4.10.2: CAN Bus (XPL (J7), XP2 (J8))
Mating Connector
8-position, modular connector (RJ-45 style). Copley Controls provides the following assemblies:
Prefabricated 10 ft cable, PN XPL-NC-10
Prefabricated 1 ft cable, PN XPL-NC-01
Terminator Plug, PN XPL-NT
A diagram of the female connector is shown below.
Pin Description*
Pin
Signal
Function
1
CAN_H
CAN_H bus line (dominant high)
2
CAN_L
CAN_L bus line (dominant low)
3
CAN_Gnd
Ground / 0 V / V-
4
--
No connection
5
--
Pass through to second connector, no internal connection
6
CAN_SHLD
Pass through to second connector, no internal connection
7
CAN_Gnd
Ground / 0 V / V-
8
CAN V+
Pass through to second connector, no internal connection
*Table applies to both CAN connectors
CAN Bus Wiring Diagram
The XPL drive uses connector J7. The XP2 drive uses connector J8.
1 2 3 4 5 6 7 8
Drive Jx
CAN +
CAN
-
CAN Gnd
CAN +
CAN
-
CAN Gnd
Note 1: If this is the last amplifier on the network,
use Copley Terminator Plug PN XPL-NT
to terminate the bus.
CAN Network
CAN Network
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Opto-isolation

Table of Contents