EasyManua.ls Logo

Copley Controls Xenus Plus Series - Power Output

Copley Controls Xenus Plus Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 66
3.3: Power Output
Model
XEL-230-18 (-R)*
XPL-230-18 (-R)*
XML-230-18 (-R)*
XEL-230-36 (-R)*
XPL-230-36 (-R)*
XML-230-36 (-R)*
XEL-230-40 (-R)*
XPL-230-40 (-R)*
XML-230-40 (-R)*
XE2-230-20 (-R,-N*)
XP2-230-20 (-R,-N*)
XM2-230-20 (-R,-N*)
800-1819
800-1887*
800-1818
Peak Current
18 Adc
[12.7 Arms]
36 Adc
[25.5 Arms]
40 Adc
[28.3 Arms]
20 Adc
[14 Arms]
9 Adc
[6.36
Arms]
Peak Current
Time
1 Second
Continuous
Current
6 Adc
[4.24 Arms]
12 Adc
[8.5 Arms]
20 Adc
[14.1 Arms]
10 Adc
[7 Arms]
4.5 Adc
[3.18
Arms]
Efficiency
>97% @ 230 Vac and rated continuous current
Output Type
3-phase IGBT inverter
16 kHz center-weighted PWM
space-vector modulation
PWM Ripple
Frequency
32 kHz
Minimum Load
Inductance
400 uH line-to-line**
NOTE: See Xenus Plus Filter (p. 148)
Capacitor
Discharge
Wait 5 minutes after disconnecting mains power before handling
* Heat sinking and/or forced air cooling required for continuous output power rating
** Consult factory for operation with inductance lower than 400 uH

Table of Contents

Related product manuals