EasyManua.ls Logo

Copley Controls Xenus Plus Series - Analog Output; Digital Outputs; Analog Outputs

Copley Controls Xenus Plus Series
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 70
3.10: Analog Output
XEL/XPL/XML
Channels
1
Type
Single-ended
Range
0-5 Vdc
Resolution
12 Bit
NOTE: There are no analog outputs available on XE2/XP2/XM2/800-1818/800-1819 drives.
3.11: Digital Outputs
XEL/XPL/XML
Channels
6 (OUT1~OUT6)
OUT1~OUT 2
OUT3
OUT4~OUT5
OUT6
Type
Current-sinking, open drain MOSFET with
External flyback diode required if driving
inductive loads
High-speed
5Vdc CMOS
buffer
Opto-isolated
Darlingtons
with 36V
Zener diodes
across
outputs
Opto-isolated motor
brake control,
current-sinking with
flyback diode to
+24V
Maximum
Voltage
+40 Vdc
5Vdc
30Vdc
+32 Vdc
Maximum
Sink Current
1 Adc
±32 mA
20 mA
1 Adc
Low Level
Output
Resistance
< 0.2
Not
applicable
(Rout only
applies to
MOSFET
outputs)
Not applicable
(Rout only
applies to
MOSFET
outputs)
0.14
Function
Programmable
Brake/Programmable
XE2/XP2/XM2/800-1818/800-1819/800-1887
Channels
XE2/XP2/XM2/800-1818: 7 (OUT1~OUT7), 800-1819/800-1887: 5 (OUT1~OUT3,
OUT6~OUT7)
OUT1~OUT 5
OUT 6~OUT 7
Type
Opto-isolated MOSFET SSR with 1 series
resistor and 36V Zener flyback diodes across
outputs
Opto-isolated, current-sinking with flyback
diode to +24 Vdc
Maximum
Voltage
30Vdc
+32 Vdc
Maximum Sink
Current
300 mA
1 Adc
Low Level
Output
Resistance
Not applicable
0.14
Function
Programmable
Note: 800-1819 and 800-1887 do not utilize
OUT4~5
Brake/Programmable

Table of Contents

Related product manuals