Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 80
3.24: Mechanical and Environmental
XEL/XPL/XML
Size
7.92 in (201,2 mm) X 5.51 in (139,9 mm) X 2.31 in (58,7 mm)
Weight
Driver without Heat Sink
Low profile (HL) Heat Sink
Standard (HS) Heat Sink
3.0 lb (1.36 kg)
Add 1.86 lb (0.84 kg)
Add 3.1 lb (1.40 kg)
Ambient Temperature
Storage
Operating
-40 to +85°C
0 to +45°C
Humidity
0% to 95%, non-condensing
Contaminants
Pollution degree 2
Environment
IEC60068-2: 2007
Cover Material
Meets UL Spec 94 V-0 Flammability Rating
Cooling
Heat sink and/or forced air cooling required for continuous power output
XE2/XP2/XM2/800-1818/800-1819/800-1887
Size
XE2/XP2/XM2 (non “-N” models)/800-1819:
- 9.24 in (234,7 mm) X 5.42 in (137,6 mm) X 3.59 in (91,1 mm)
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887:
- 9.24 in (234,7 mm) X 5.57 in (141,6 mm) X 2.31 in (58,7 mm)
Weight
XE2/XP2/XM2 (non “-N” models)/800-1819: 4.19 lb (1.90 kg)
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887: 3.13 lb (1.42 kg)
Ambient Temperature
Storage
Operating
-40 to +85°C
0 to +40°C
Altitude
≤ 2000 m per IEC 60068-2-13:1983 if an SPD is used to establish an OVC II
environment
≤ 4000 m per IEC 60068-2-13:1983 if a mains isolation transformer is used to establish
an OVC II environment
Humidity
0% to 95%, non-condensing
Contaminants
Pollution degree 2
Ingress Protection
IP20
Vibration
2 g peak, 10~500 Hz (sine), IEC60068-2-6
Shock
10 g, 10 ms, half-sine pulse, IEC60068-2-27
Environment
IEC60068-2: 2007
Cooling
XE2/XP2/XM2 (non “-N” models)/800-1819:
- Integrated heatsink and cooling fan provide required cooling
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887:
- Dependent on mounting orientation and ambient airflow