Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 121
4.11.4: Isolated Control - XE2/XP2/XM2/800-1818 (J9)
J9 is a 26 position male D-sub connector used for isolated controls
Mating Connections
Description
Manufacturer PN
Wire Size
26 Position, High-Density D-Sub Female Solder
Style Connector
Norcomp 180-026-
203L001
24 - 30 AWG
Back shell
Norcomp 979-015-
020R121
Solder style connector included in Connector Kits XE2-CK, XP2-CK and XM2-CK.
Pin connections for the bulkhead connector on the drive are shown here:
XE2/XP2/XM2 Pin Description
Pin
Signal
Function
1
Frame Ground
Cable shield connection.
2
IN6 GPI
Optically isolated programmable input.
3
IN7 GPI
4
IN8 GPI
5
IN9 GPI
6
COM1
Common signal for first group of optically isolated programmable inputs (IN6-IN9)
7
IN16 GPI
Optically isolated programmable input.
8
IN17 GPI
9
IN18 GPI
10
OUT1- GPI
Optically isolated programmable output negative signal.
11
OUT2- GPI
12
OUT3- GPI
13
OUT4- GPI
14
OUT5- GPI
15
N/C
No connection.
16
N/C
No connection.
17
COM2
Common signal for first group of optically isolated programmable inputs (IN16-IN19)
18
IN19 GPI
Optically isolated programmable input.
19
OUT1+ GPI
Optically isolated programmable output positive signal.
20
OUT2+ GPI
Optically isolated programmable output positive signal.
9
1
18
26
19
10

Table of Contents