Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 46
XPL J6 NET Indicator: CANopen RUN and ERR States
RUN (Green) LED: CANopen State Machine Mode of Operation
Indicator
State
Diagram
Blinking green
Pre-operational.
Steady green
Operational
Single flash green
Stopped
ERR (Red) LED: CANopen Physical Layer Status
Single flash red
Warning Limit
Reached
Double flash red
Error Control Event
Triple flash red
Sync Error
Steady red
Bus Off
200
ms
off
200
ms
green
off
green
green
200
ms
off
1 second
red
200
ms
off
1 second
red
200
ms
off
1 second
200
ms
red
200
ms
off
1 second
200
ms
200
ms
red
off