Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 92
4.3.2: (J3, J4) XE2/XP2/XM2/800-1818/800-1819/800-1887
Mating Connector
Euro-style, 4 position, 5.08 mm pluggable female terminal block
12 AWG, 600 V
Shielded cable required for CE compliance
Wire Insertion/Extraction Tool
Standard connector and tool are included in Connector Kits XE2-CK, XM2-CK, and XP2-CK.
Motor frame ground and cable shield
Phase V output of drive (use for DC motor connection)
Phase U output of drive (use for DC motor connection)
Brushless Motor Wiring Diagram
Brush Motor Wiring Diagram