Xenus Plus User Guide 16-01344 Rev 06
Copley Controls 97
4.5.2: XE2/XP2/XM2/800-1818/800-1819/800-1887 (J5)
The following information is for XE2/XP2/XM2/800-1819/800-1887 drives only.
Mating Connector
Euro-style 3.5 mm, 5 position pluggable female terminal block.
Wire Insertion/Extraction Tool
Standard connector and tool are included in Connector Kits XE2-CK, XP2-CK and XM2-CK.
+24 Vdc Logic power supply return
Return or low side of motor brake B.
Return or low side of motor brake A.
+24 Vdc Logic power supply
Logic Supply / Brake Wiring Diagram
Note that the +24Vdc supply must be a SELV or PELV type in applications using the XE2/XP2/XM2 STO
feature. See the Xenus Plus Dual-Axis STO Manual for further details.
Drive J5
Isolated Logic
Pow er Supply
for Brake A
J5-5
J5-4
+24 V
BRK-A
RTN
Brake A
J5-3
J5-2
J5-1
BRK +24 Vdc
BRK-B
Isolated Logic
Pow er Supply
for Brake B
Brake B
+24 Vdc
Power
Supply
(Required)