ABS 2.0 Operator’s Manual
© 2019, Cornelius Inc. - 7 - Publication Number: 621058590OPR
NORMAL OPERATIONS
LOCATION, POWER ON UNIT & USAGE
Location Of Unit
Locate the dispenser so that the following requirements are satisfied:
1. Unit is not to be installed in an area where a water jet (power washer) is used.
2. Unit must be locat
ed in an area with a level floor surface. The unit must be installed within 2° of level for
the unit to operate properly.
3. The unit should only be installed in a location where it
s use and maintenance is restricted to trained per-
sonnel.
4. Unit must be located in an area with nearest access to floor drain port, preferably under the foot print of
un
it.
5. The clearance above top of the unit must be open and the front of the unit must be open to the room.
Th
ese clearances must be provided to allow for proper air flow and to allow access to the ice bin for refill-
ing.
Power On Unit
!
DANGER:
To avoid possible fatal electrical shock or serious injury to the operator, it is highly recommended that a GFI
(ground fault circuit interrupter) be installed in the electrical power circuit.
The machine is equipped with a power cord (hot, neutral and ground) and is plugged into any standard wall
o
utlet capable of handling as shown in Table 3 on page 7.
Table 3.Product electrical requirement
Unit Plug Type Region Voltage-Frequency-Phase Amps
ABS 2.0 IEC-NEMA 5-15P North America’s 120 VAC – 60 Hz – 1Ph 15
ABS 2.0
European CENELEC Member
Co
untries
220-240 V, 50-60 Hz – 1Ph 10
ABS 2.0 BS1363A
Great Britain/Ireland
220-240 V, 50-60 Hz – 1Ph 13
ABS 2.0 AS3112 Australia 220-240 V, 50-60 Hz – 1Ph 10
CAUTION:
!
The electrical circuits must be properly fused (Slow-blow type fuses). DO NOT use HACR circuit
breakers on the circuit of the unit.
HACR circuit breakers may not react to voltage surges or spikes that can
damage the electronics
NOTE: The electrical outlets must be accessible for ease of connecting and disconnecting the
di
spenser cords. No other electrical appliances should be connected to these electrical
circuits.
NOTE: All electrical wiring must conform to national and local electrical codes.