Page 27
when the time zone programmed at address P290E starts.
Option 3 Disable stay mode exit delay - If this option is on the exit delay for partition "A" becomes “0”
when arming stay mode (the delay will still apply to full arm unless option 4 is also on).
Option 4 Disable set mode exit delay - If this option is on the exit delay for partition "A" becomes “0”
when arming the panel (the delay will still apply to stay mode unless option 3 is also on).
Option 5 Disable stay mode entry delay - If this option is on then all zones are instant in stay mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in full
arm mode unless option 6 is also on).
Option 6 Disable set mode entry delay - If this option is on then all zones are instant in full set mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in stay
mode unless option 5 is also on).
Option 7 Use special stay mode entry delay -
If this option is on then all zones use the special Stay
Mode entry delay (P540E) in stay mode and the normal delays programmed at addresses
P511E—P526E are ignored.
Option 8 Send alarms and bypasses in stay mode - If this option is on then all alarms and zone
bypasses in Stay mode will be reported via the dialler in Contact ID. Only zone alarms will be
reported if using Domestic/ Voice or Pager reporting formats. You should also note that if a Stay
mode alarm is not kissed of in Domestic/ Voice or Pager mode and the alarm is not disarmed,
when the dialler test time comes around, the zone alarms will report again. If this is not desired
you can stop this from happening by turning of all days for the test time at address P815E.
Note: P403E is the same as above but applies to Area B Time & Delay options
Note: P503E is the same as above but applies to Area C Time & Delay options
PARTITIONS MISC KEYPAD OPTIONS
PARTITION "A" -
P301E
PARTITION "B" -
P401E
PARTITION "C" -
P501E
P301E 1E Cannot Arm if not Ready
2E Arm key required before code to set
3E Stay key required before code to arm Stay Mode
4E Code required to arm area
5E Control function requires code
6E Control function toggles
7E Control function is momentary
8E Control Button disables "Day/Chime" mode or directly Controls Outputs
Option 1 Cannot Arm if not Ready - This option if turned on will inhibit arming of Area “A” if any zone in area A
is unsealed (Not Ready). If the option is off, the area can be armed with zones unsealed but the panel
will either auto-exclude the zone or go into alarm at the end of the exit delay depending upon other
option settings. If required, certain zones can be exempted from this feature if they are in low security
areas, allowing the area to be armed with a zone/s unsealed, by selecting the zones at addresses
P460E AND P480E. This option does not apply to Stay mode.
Option 2
Arm key required before code to set
- This option determines if the "ARM" key must be pressed
before a code is entered to set Area "A". This option must be enabled where a keypad is assigned to
more than one area.
Option 3
Stay key required before code to arm Stay Mode
- This option determines if the "STAY" key is a
single button function or must be pressed followed by a code to turn on Stay Mode in Area "A". This
option must be enabled where a keypad is assigned to more than one area. If off, Stay mode is turned
on by pressing the Stay button only, if on, you must enter a code after pressing the stay button. When
Arming Stay Mode, if the user presses the “Enter” button during the exit delay, this will cancel any
1 - - - - - - 8
A Misc Options 3